Home/ Recalls/ 11V581000
Recall

Kingmor Resb — 11V581000

NHTSA ID
11V581000
Make
Kingmor
Model
Resb
Years Affected
2010
Recall Date
2011-12-08
Component
EQUIPMENT:APPLIANCE:AIR CONDITIONER
Units Affected
850
Completion Rate
Mfr Campaign No.

Summary

KINGMOR SUPPLY INC. (KINGMOR) IS RECALLING CERTAIN MODEL YEAR 2001 THROUGH 2012 IC RE, FE, AND CE SCHOOL BUSES EQUIPPED WITH CARRIER GENV EM-1 EVAPORATOR UNITS (EM-1) MANUFACTURED FROM JANUARY 1, 2006 THROUGH DECEMBER 2010, CONTAINING A DELPHI PACK-CON III FUSE HOLDER IN AN ALLIED MOTION MOTOR ASSEMBLY; EM-1 UNIT PART NUMBERS 77-62112-XX AND 77-62512-XX, STARTING WITH SERIAL NUMBER KNT90890232 TO SERIAL NUMBER NNE91230058, DUE TO TIME, TEMPERATURE, AND/OR VIBRATION, THE FUSE MAY LOOSEN IN THE FUSE HOLDER RESULTING IN HIGH RESISTANCE AND ARCING.

Consequence

IF SUFFICIENT ARCING OCCURS, THE FUSE HOLDER MAY MELT, AND MAY BE ACCOMPANIED BY FLAME, SMOKE AND POTENTIAL FIRE.

Remedy

KINGMOR WILL NOTIFY OWNERS AND PROVIDE INFORMATION ON HOW TO OBTAIN THE RETROFIT KIT FROM CARRIER ALONG WITH REPAIR INSTRUCTIONS. THIS SERVICE WILL BE PERFORMED FREE OF CHARGE. THE SAFETY RECALL BEGAN ON FEBRUARY 21, 2012. (SEE CARRIER'S RECALL CAMPAIGN 11E-003.) OWNERS MAY CONTACT CARRIER AT 1-800-793-4741 OR KINGMOR AT 1-540-433-0073.

Affected Vehicles

Kingmor Resb
Model Years: 2010

2010 Kingmor Resb